Cowwarr, Gippsland Workshop

Direct Bench Diagnostics, ASIC Repair & Facility Electrical Audits

Focus Layer Core provides rigorous crypto mining education grounded in electrical safety, thermodynamics, and component-level circuit repair. Learn directly on operational test benches in our regional Victorian facility.

ASIC Masterclass (Flagship) All Workshops & Audits
Location: 27 River Road, Cowwarr VIC
Format: Small Group Lab & On-Site Inspections
Hardware test bench with oscilloscope and multimeter in Cowwarr lab
Gippsland Hardware Lab Individual workbench stations with real Antminer S19 and Whatsminer test rigs.
Flagship Technical Program

Hands-On ASIC Hardware & Diagnostics Masterclass

A two-day intensive workshop taught on physical hardware in Cowwarr. Move beyond software reboots to isolate domain voltage dropouts, repair signal chains, and re-apply thermal interface materials.

Domain Signal Tracing

Master the five critical test signals across serial hashboard domains: Clock (CLK), Transmit (TX), Receive (RX), Reset (RST), and LDO regulator rail voltages using digital multimeters and bench oscilloscopes.

Thermal Interface Renewal

Replace baked thermal paste with calibrated phase-change pads. Learn torque-limiting screwdriver sequence techniques to prevent substrate warping and eliminate chip hot-spots.

Power Supply & Busbar Safety

Diagnose 12V and 24V switch-mode server power supplies, calculate inrush currents, inspect bulk filter capacitors, and prevent catastrophic busbar arc faults.

Course Rate: $1,450 AUD (Includes Hardware Starter Kit & Lab Materials) Next scheduled session: 17–18 October 2026 in Cowwarr, Victoria.
View Full Masterclass Syllabus
Complete Curriculum & On-Site Audits

Professional Mining Education & Engineering Audits

Explore All Services
Hands-On ASIC Hardware & Diagnostics Masterclass
In-Person 2-Day Practical Workshop 16 Hours (2 Full Days)

Hands-On ASIC Hardware & Diagnostics Masterclass

An intensive two-day practical workshop in our Cowwarr lab covering hashboard voltage testing, thermal paste re-application, control board firmware flashing, and component-level fault isolation.

$1,450 AUD per attendee (includes diagnostic toolkit & lab materials)
Site Electrical & Three-Phase Load Audit
On-Site Physical Audit (Regional Victoria & NSW border) 1 Full Day On-Site + Formal Engineering Report

Site Electrical & Three-Phase Load Audit

An on-site technical inspection of your shed, workshop, or commercial facility electrical infrastructure to determine safe continuous mining capacity.

$1,850 AUD base audit + travel allowance for remote sites
Facility Airflow & Thermal Engineering Workshop
1-Day Small Group Workshop & Design Lab 8 Hours (1 Day)

Facility Airflow & Thermal Engineering Workshop

Practical training in designing positive/negative pressure ventilation, hot aisle isolation, and acoustic attenuation for high-heat environments.

$880 AUD per participant
Solar & Off-Grid Mining Feasibility Assessment
Remote Modeling & Dedicated Consultation Session 2 Weeks Analysis + 2-Hour Strategy Debrief

Solar & Off-Grid Mining Feasibility Assessment

Custom engineering study and modeling to evaluate agricultural solar curtailment, generator integration, and diurnal mining scheduling.

From $1,600 AUD (Scope dependent on generator/PV size)
Immersion & Dielectric Fluid Practical Lab
1-Day Advanced Lab Session 7 Hours (1 Day)

Immersion & Dielectric Fluid Practical Lab

Hands-on immersion workshop covering single-phase synthetic fluids, dry cooler heat rejection, pump hydraulic curves, and gasket safety.

$990 AUD per participant
Facility Infrastructure

The Cowwarr Hardware Testing Facility

Located in Central Gippsland, our dedicated 250m² educational workshop features fully configured three-phase power feeds, calibrated airflow wind tunnels, FLIR thermal diagnostic cameras, and working single-phase immersion tanks.

  • 6 dedicated bench testing stations with isolated variable power supplies
  • Differential pressure and CFM anemometer measurement ducting
  • Live single-phase dielectric fluid cooling loop with dry cooler rejection
Tour Lab Workbenches & Schedule
Electrical workshop bench in Cowwarr with precision tools
Verified Field Case Stories

Feedback From Workshop Attendees & Site Audits

Read detailed experiences from farm operators, electrical contractors, and hardware technicians who have completed our programs.

Site Electrical & Three-Phase Load Audit

“We had 65kW of rooftop solar on our machinery shed that was being curtailed to zero export by AusNet for six months of the year. David came out to our property and spent eight hours running thermal scans on our switchboards and checking our transformer voltage drop. He discovered our sub-board neutral link was running dangerously hot at 68°C under test load. He gave our local electrician clear cable sizing schematics that allowed us to commission our 18-unit setup safely without tripping our main farm supply.”

Graeme MacIntyre
Farm Owner & Grazier • Bairnsdale, VIC
July 2026
Hands-On ASIC Hardware & Diagnostics Masterclass

“The two days in Cowwarr were packed with hands-on bench work. We disassembled Antminer S19 Pro hashboards, probed the 1.8V LDO rails with oscilloscopes, and learned how to replace dried-out thermal paste with phase-change pads. Day one felt slightly overwhelming due to the sheer volume of circuit theory and domain voltage math thrown at us before lunch, but by the end of day two I had successfully revived two test boards that had persistent chip dropouts. The physical diagnostic checklist Marcus provided is now pinned to our workshop bench.”

Sarah Lin
Facility Operations Manager • Melbourne, VIC
May 2026
Read All 5 Verified Client Case Stories →
Knowledge Base & Field Notes

Recent Electrical & Hardware Guides

Browse All Guides
Diagnosing ASIC Domain Voltage Dropouts with a Digital Multimeter

Diagnosing ASIC Domain Voltage Dropouts with a Digital Multimeter

A practical bench guide to isolating broken serial communication chains, LDO regulator faults, and failed domain capacitors on modern hashboards.

Read Technical Guide →
Managing Australian Summer Heat: Static Pressure & Airflow in Rural Sheds

Managing Australian Summer Heat: Static Pressure & Airflow in Rural Sheds

Why commercial extraction fans fail when static pressure is ignored, and how to balance intake louvers with hot aisle containment in regional sheds.

Read Technical Guide →
Three-Phase Balancing and Power Factor for High-Load Australian Installations

Three-Phase Balancing and Power Factor for High-Load Australian Installations

A deep dive into neutral current buildup, harmonic distortion from switch-mode power supplies, and AS/NZS 3000 compliance for rural workshops.

Read Technical Guide →

Book a Session or Request an Electrical Audit

Whether you need hands-on ASIC diagnostics training in our Cowwarr lab or a formal electrical load audit for your farm or commercial property, our instructors are ready to assist.

Submit an Inquiry Call 0437 216 905